Key Points:
- An automatic door bottom seal which is spring loaded to lift clear of the floor as soon as the door leaf is opened by a few millimetres.
- An acoustically designed seal for rebated applications. Mounted into a 15mm x 28mm groove that has been morticed into the bottom edge of the door.
- It is operated automatically by pressure against the door jamb on its plunger and seals when the door closes and retracts automatically when the door is opened.
Description:
14mm maximum drop, Graduated Scissor action (seal drops on hinge side before lock side).
Smoke Testing was conducted to BS EN 1634-3: 2004 smoke control tests for door and shutter assemblies, openable windows and elements of building hardware - Part 3: Smoke control test for door and shutter assemblies.
Noise Reduction Index up to Rw 51dB*
Maximum Drop: 14mm.
Aluminium carrier
Specification:
- Noise Reduction Index up to Rw 51 dB*
- Min/Max Gap: 3mm - 14mm.
- Seal Length: 730mm
- Maximum trimming: 150mm - 730mm.
Installation:
We have technical representatives who provide assistance in the selection and specification of the products on this site and should be consulted for exact installation and product suitability. Ensure an early engagement with ourselves, designers, main contractor and specialist installers before any installation. Other trades and/or manufacturers may need to be consulted. For in-depth information, specification and technical advice please call our Head Office on Tel: +(0)1329 841416 or email sales@stormflame.com
Maintenance:
All interested parties, designer, specifier, main contractor and specialist installers should provide access to allow the fire stopping seals to be regularly inspected and maintained, as well as records kept of such maintenance at minimum periods of 12 months, as required by the Regulatory Reform Order, and repaired if necessary. Reference should be made to ASFP TGD 17 Code of Practice for the Installation and Inspection of Fire Stopping.
Competency:
It is vital that those entrusted to design or install a fire stopping product have the necessary levels of competence to undertake the task professionally and thoroughly. The level of competency required will be commensurate with the expected complexity of the building. All designers must eliminate, reduce or control foreseeable risks that may arise during installation, construction or maintenance when preparing or modifying designs. Clients should ensure that the principal designer and principal contractor carry out their duties under CDM regulations. The ASFP foundation course in passive fire protection provides essential knowledge as part of demonstrating competency and understanding in this key fire protection specialism.
Additional Notes:
* The sound reduction rating will vary depending on the door density and any additional threshold & perimeter seals used in conjunction with this product, contact Stormflame for confirmation before specifying.
For further information on installation requirements please refer to the door manufacturer data to ensure the compatibility of this product, if in doubt please contact the technical team on: Tel: +(0)1329 841416 or email sales@stormflame.com
Download and review any of the following information: