Key Points:
- Raven RP10Si Door Perimeter Seal.
- Heavy duty acoustic and smoke Seal

Symbol Guide
Description:
A neat compact door stop frame seal which has proven to be an effective acoustic seal when tested in accordance with BS EN ISO 717.1.
It is quick and easy to install onto the door frame as a door stop. It is adjustable, by concealed fixing slots, for a precision fit.
The multi blade seal considerably reduces the leakage of noise and air movement. The minimum deflection of the sealing fins creates maximum efficiency, offering a large tolerance for door movement over time. The seal can be mitred or butt jointed to give an integrated aesthetic appearance.
Note: If fixing to rebated frames of single doors, specify a long backset door latch.
Specification:
- Location: Head and jambs of single and double butt hinged doors.
- Min/Max Gap: 0mm to 10mm.
- Fixing: Zinc plated, cross recess head S.T. screws of the appropriate size are supplied, Fixing holes are pre drilled and are slotted to allow the seals to be fitted accurately and to allow adjustments to be made for building movement.
- Seal Material: Silicon rubber (SE) (Charcoal).
- Replacement Seal: RP310si.
- Standard Finish: Anodised Satin Clear.
- Used in Conjunction: Raven Door Bottom Seals, Astragals and Thresholds.
- Supplied: Single Door Set - 2 x 2.1m plus 1 x 1m seals
Installation:
We have technical representatives who provide assistance in the selection and specification of the products on this site and should be consulted for exact installation and product suitability. Ensure an early engagement with ourselves, designers, main contractor and specialist installers before any installation. Other trades and/or manufacturers may need to be consulted. For in-depth information, specification and technical advice please call our Head Office on Tel: +(0)1329 841416 or email sales@stormflame.com
Maintenance:
All interested parties, designer, specifier, main contractor and specialist installers should provide access to allow the fire stopping seals to be regularly inspected and maintained, as well as records kept of such maintenance at minimum periods of 12 months, as required by the Regulatory Reform Order, and repaired if necessary. Reference should be made to ASFP TGD 17 Code of Practice for the Installation and Inspection of Fire Stopping.
Competency:
It is vital that those entrusted to design or install a fire stopping product have the necessary levels of competence to undertake the task professionally and thoroughly. The level of competency required will be commensurate with the expected complexity of the building. All designers must eliminate, reduce or control foreseeable risks that may arise during installation, construction or maintenance when preparing or modifying designs. Clients should ensure that the principal designer and principal contractor carry out their duties under CDM regulations. The ASFP foundation course in passive fire protection provides essential knowledge as part of demonstrating competency and understanding in this key fire protection specialism.
Additional Notes:
For further information on installation requirements please refer to the door manufacturer data to ensure the compatibility of this product, if in doubt please contact the technical team on: Tel: +(0)1329 841416 or email sales@stormflame.com